一、產品特性 I Product Feature HSD-002主要成份為高錳酸鉀,用于配合前制程將經過膨松劑軟化之膠渣進一步清除,使孔壁生成親水性,利于后制程化學銅之進行,內含特殊穩定劑,使錳酸鹽沉淀減少。 The main content of HSD-002 is potassium permanganate and is used to assist the former procedure to further remove the smear softened by sweller; it can turn the hole-wall to behydrophilic, which is beneficial for later procedure of electroless copper; it contains special stabilizer, which can reduce the deposit of manganate.
二、配槽方法 II Makeup Method
1L槽液 1L solutioin |
主要作用 Main Function |
體積(ml) Volume |
純水 Pure water |
溶劑 Solvent |
900ml |
片堿 Sodium hydroxide |
提供堿環境 Provide alkaline environment |
50g/L |
| HSD-002 |
除膠渣 Desmear |
60g/L |
操作條件 III Operating Condition
組份/參數 Component/Parameter |
最佳值/工作范圍/要求 Optimal value/Work Scope/Requirement |
溫 度 Temperature |
75℃(70-80℃) |
時 間 aTime |
8min (10-14min) |
搖 擺 Swing |
輕微的機械擺動 Slight mechanical swing |
槽體材質 Material of bath |
P.P材料 PP material |
加熱器 Heater |
鈦、石英或鐵弗龍 Titanium, quartz or Teflon |
過濾泵 Filter pump |
用不銹鋼(316)材料制造 Made of stainless steel (316) |
四、添加量 IV Additive Volume 每生產1000ft2補加HSD-OO2:1.5KG;NaOH:1L。 Supplement 1.5KG HSD-OO2: and 1L NaOH:for producing 1000ft2; 五、控制與維護 V Control and Maintenance 每升工作液處理500-700ft2時換缸(如有再生器,一般不需換缸)。 Change bath when each litre of working solution processes 500-700ft2 (if there is a regenerator, changing bath will not be necessary) 六、安全防護 VI Safety Protection 使用時請佩戴眼罩、手套及穿安全防護衣。若藥液不慎濺及皮膚、眼睛時應用大量清水清洗,嚴重者應立即就醫診治。 When using it, please wear eyeshade, gloves and protective clothes; in case that solution spatters into eye or on skin, immediately flush with plenty of clean water and get medical treatment if necessary.. |